Test Procedure


At eTeknix we take the power supply testing procedure very seriously. For all power supply reviews we used a variety of Chroma machines and other digital power machinery provided by Enermax in their European test labs. We would like to say a huge thank you to Enermax for making this power supply testing possible.

The test machinery included the following:

  • A Chroma 6314A power supply load tester with two add on 6314 modules to support up to six 12 volt rails.
  • A Chroma Digital Power Meter Model 66202
  • A Custom-made Enermax PCB circuit board to connect all the appropriate power supply cables
  • A Tektronix TDS 3014C Digital Phosphor Oscilloscope
  • A Voltcraft DT-10L Laser Tachometer

The eTeknix test procedure involves:

  • Testing each power supply at 20/40/60/80/100% load (with balanced load across all rails) and measuring PFC (power factor correction), efficiency (actual power divided by power “pulled at the wall”) and voltage regulation (deviance from expected voltages of 3.3/5/12).
  • Measuring ripple and noise with an oscilloscope at 20/40/60/80/100% load.
  • Measuring voltage regulation and ripple/noise at Maximum 12v loads and maximum 3.3/5v loads while keeping the -12v and 5vsb consistently at 0.1A and 1A on the rail(s) not being tested. For example under 12v crossload we would load the 12v rail to its maximum and place 0.1A on the -12v and 5vsb as well as 1A on the 3.3v and 5v rails.
  • Measuring fan speed after a stabilisation period of five minutes at each load scenario using the Voltcraft DT-10L laser tachometer and a reflective strip on the fan.

Other things to consider are that

  • We recognise that a single yellow 12 volt cable can provide only 6 Amps before overheating (which corrupts voltage regulation and efficiency) and so we used an adequate number of cables for each power supply.
  • Our power supply tester was capable of only 50 Amps on the 12 volt 1 rail, 50 Amps on the 12 volt 2 rail and 25 Amps on rails 3-6. This meant that for single 12 volt power supplies with rail Amps above 50 we had to split them virtually over two rails to maximise their load. There are no power supplies that we tested that have more than 50 Amps over two rails so this was only an issue for single 12 volt rail power supplies.
  • We use the same time scale and horizontal millivolt scale on our oscilloscope for all noise and ripple tests.
  • Deviance is the terminology used to represent the way voltages diverge from their expected values.

Page: 1 2 3 4 5 6 7 8 9 10

Ryan Martin

Disqus Comments Loading...

Recent Posts

Razer Naga V2 HyperSpeed – Ergonomic Wireless MMO Gaming Mouse

19 Programmable Buttons ergonomically placed for optimized control: Whether you’re mapping out the essentials or…

18 hours ago

Razer Cynosa Lite – Essential Gaming Keyboard

Powered by Razer Chroma Single zone lighting with 16.8 million colors: Choose from 16.8 million…

18 hours ago

Razer BlackShark V2 X – Multi-Platform Wired Esports Headset

Razer TriForce 50mm Drivers for high-end audio performance: Our new, cutting-edge proprietary design divides the…

18 hours ago

ASUS ROG STRIX B550-F GAMING Motherboard

AM4 socket: ready for AMD Ryzen 3rd generation processors.Manageability : WOL by PME, PXE Connectivity…

18 hours ago

PDP Rematch + Case Bundle Star Spectrum Nintendo Switch

3.5mm jack supports in-game audio and USB-chat, while D-pad controls easily adjust the volume Customize…

18 hours ago

ASUS ROG Cetra True Wireless Gaming Headphones

Also available in Black Touch control: Simple quick-touch controls enable rapid in-game adjustments. Active Noise…

18 hours ago