Test Procedure


At eTeknix we take the power supply testing procedure very seriously. For all power supply reviews we used a variety of Chroma machines and other digital power machinery provided by Enermax in their European test labs. We would like to say a huge thank you to Enermax for making this power supply testing possible.

The test machinery included the following:

  • A Chroma 6314A power supply load tester with two add on 6314 modules to support up to six 12 volt rails.
  • A Chroma Digital Power Meter Model 66202
  • A Custom-made Enermax PCB circuit board to connect all the appropriate power supply cables
  • A Tektronix TDS 3014C Digital Phosphor Oscilloscope
  • A Voltcraft DT-10L Laser Tachometer

The eTeknix test procedure involves:

  • Testing each power supply at 20/40/60/80/100% load (with balanced load across all rails) and measuring PFC (power factor correction), efficiency (actual power divided by power “pulled at the wall”) and voltage regulation (deviance from expected voltages of 3.3/5/12).
  • Measuring ripple and noise with an oscilloscope at 20/40/60/80/100% load.
  • Measuring voltage regulation and ripple/noise at Maximum 12v loads and maximum 3.3/5v loads while keeping the -12v and 5vsb consistently at 0.1A and 1A on the rail(s) not being tested. For example under 12v crossload we would load the 12v rail to its maximum and place 0.1A on the -12v and 5vsb as well as 1A on the 3.3v and 5v rails.
  • Measuring fan speed after a stabilisation period of five minutes at each load scenario using the Voltcraft DT-10L laser tachometer and a reflective strip on the fan.

Other things to consider are that

  • We recognise that a single yellow 12 volt cable can provide only 6 Amps before overheating (which corrupts voltage regulation and efficiency) and so we used an adequate number of cables for each power supply.
  • Our power supply tester was capable of only 50 Amps on the 12 volt 1 rail, 50 Amps on the 12 volt 2 rail and 25 Amps on rails 3-6. This meant that for single 12 volt power supplies with rail Amps above 50 we had to split them virtually over two rails to maximise their load. There are no power supplies that we tested that have more than 50 Amps over two rails so this was only an issue for single 12 volt rail power supplies.
  • We use the same time scale and horizontal millivolt scale on our oscilloscope for all noise and ripple tests.
  • Deviance is the terminology used to represent the way voltages diverge from their expected values.

Page: 1 2 3 4 5 6 7 8 9 10

Ryan Martin

Disqus Comments Loading...

Recent Posts

Alphacool Apex Stealth Metal Power Fan 3000rpm White

High-quality, elegant as well as timeless design and technical innovation these are the features of…

1 day ago

MSI 32″ MAG 325CQRXF 2560×1440 VA 240Hz 1ms A-Sync Curved Gaming Monitor

Provide ultra-fast 1ms GTG response time, make sure the intensity and purity of colors when…

1 day ago

be quiet! Pure Loop 360 Performance CPU Water Cooler

Pure Loop 360m is the new high-performing and silent All-in-One water cooling unit of be…

1 day ago

noblechairs ICON Gaming Chair – White Edition

ICON gaming chair from the White Series featuring a high-tech vinyl upholstery Two memory foam…

1 day ago

Glorious Model O PRO Wireless Optical Gaming Mouse

Limited Edition wireless gaming mouse from Glorious Forge Available in three bold colours: Blue Lynx,…

1 day ago

ASUS ROG Ryujin II 240 Performance AIO CPU Liquid Cooler with OLED Display

The flagship ROG Ryujin II all-in-one cooler delivers ultimate thermal performance for gamers looking for…

1 day ago