Featured

Antec EarthWatts Platinum 650W Review

Test Procedure


At eTeknix we take the power supply testing procedure very seriously. For all power supply reviews we used a variety of Chroma machines and other digital power machinery provided by Enermax in their European test labs. We would like to say a huge thank you to Enermax for making this power supply testing possible.

The test machinery included the following:

  • A Chroma 6314A power supply load tester with two add on 6314 modules to support up to six 12 volt rails.
  • A Chroma Digital Power Meter Model 66202
  • A Custom-made Enermax PCB circuit board to connect all the appropriate power supply cables
  • A Tektronix TDS 3014C Digital Phosphor Oscilloscope
  • A Voltcraft DT-10L Laser Tachometer

The eTeknix test procedure involves:

  • Testing each power supply at 20/40/60/80/100% load (with balanced load across all rails) and measuring PFC (power factor correction), efficiency (actual power divided by power “pulled at the wall”) and voltage regulation (deviance from expected voltages of 3.3/5/12).
  • Measuring ripple and noise with an oscilloscope at 20/40/60/80/100% load.
  • Measuring voltage regulation and ripple/noise at Maximum 12v loads and maximum 3.3/5v loads while keeping the -12v and 5vsb consistently at 0.1A and 1A on the rail(s) not being tested. For example under 12v crossload we would load the 12v rail to its maximum and place 0.1A on the -12v and 5vsb as well as 1A on the 3.3v and 5v rails.
  • Measuring fan speed after a stabilisation period of five minutes at each load scenario using the Voltcraft DT-10L laser tachometer and a reflective strip on the fan.

Other things to consider are that

  • We recognise that a single yellow 12 volt cable can provide only 6 Amps before overheating (which corrupts voltage regulation and efficiency) and so we used an adequate number of cables for each power supply.
  • Our power supply tester was capable of only 50 Amps on the 12 volt 1 rail, 50 Amps on the 12 volt 2 rail and 25 Amps on rails 3-6. This meant that for single 12 volt power supplies with rail Amps above 50 we had to split them virtually over two rails to maximise their load. There are no power supplies that we tested that have more than 50 Amps over two rails so this was only an issue for single 12 volt rail power supplies.
  • We use the same time scale and horizontal millivolt scale on our oscilloscope for all noise and ripple tests.
  • Deviance is the terminology used to represent the way voltages diverge from their expected values.

Page: 1 2 3 4 5 6 7 8 9 10

Ryan Martin

Disqus Comments Loading...

Recent Posts

Jonsbo HX6250 Single Tower Six Heat Pipes CPU Cooler

Highly efficient single tower CPU Cooler All copper brazing process for maximum thermal conductivity 140mm…

4 days ago

NZXT Relay 7.1 Surround Sound Gaming Headset PC Black

The NZXT Relay Headset features certified Hi-Res Audio – hear every detail, from enemy footsteps…

4 days ago

be quiet! Black Pure Base 500DX Windowed ARGB PC Gaming Case

Upgrade your gaming setup with the Pure Base 500DX case from be quiet! This impressive…

4 days ago

High End Gaming PC with NVIDIA GeForce TX 4070 and AMD Ryzen 7 7700 Powered by ASUS

This 3XS Gamer RTX features the 12GB ASUS GeForce RTX 4070 DUAL OC graphics card…

4 days ago

Corsair MP600 ELITE /w Heatsink 2TB White M.2 PCIe NVMe SSD/Solid State Drive for PS5

The CORSAIR MP600 ELITE PCIe Gen4 x4 NVMe M.2 SSD for PS5 provides high-performance storage…

4 days ago

NZXT H6 Flow RGB Black Compact Dual-Chamber Tempered Glass PC Case

The H6 Flow's innovative compact design emphasizes GPU cooling with a strategically angled front corner,…

4 days ago